Тема: Задержки при наборе
Длина пачкорда какая?
и на какой транк лидинг намбер направлен? в итоге все валится на опера ,да? или еще что происходит?
в QD блатных не прописывал?
Index,Date,Time,Error Code,Sub Code,Error Level,Error Message
0,21/07/2010,16:23:10,390, 11101,Minor,Digital signal synchronization established
1,21/07/2010,16:23:10,301, 11101,Minor,Digital trunk RAI reception
2,21/07/2010,16:22:41,390, 11101,Minor,Digital signal synchronization established
3,21/07/2010,16:22:41,301, 11101,Minor,Digital trunk RAI reception
4,21/07/2010,16:22:37,390, 11101,Minor,Digital signal synchronization established
5,21/07/2010,16:22:37,301, 11101,Minor,Digital trunk RAI reception
6,21/07/2010,16:21:59,391, 11101,Minor,Data Link established
7,21/07/2010,16:21:58,305, 11101,Minor,Data Link failure
8,21/07/2010,16:21:33,390, 11101,Minor,Digital signal synchronization established
9,21/07/2010,16:21:33,301, 11101,Minor,Digital trunk RAI reception
10,21/07/2010,16:21:32,390, 11101,Minor,Digital signal synchronization established
11,21/07/2010,16:21:31,301, 11101,Minor,Digital trunk RAI reception
12,21/07/2010,16:20:33,390, 11101,Minor,Digital signal synchronization established
длина метров 5, в QD только перехваты, транк 6 как на плате потоковой
да и набираю я 701 а он высвечивает только 7
Index,Date,Time,Error Code,Sub Code,Error Level,Error Message
0,21/07/2010,16:23:10,390, 11101,Minor,Digital signal synchronization established
1,21/07/2010,16:23:10,301, 11101,Minor,Digital trunk RAI reception
2,21/07/2010,16:22:41,390, 11101,Minor,Digital signal synchronization established
3,21/07/2010,16:22:41,301, 11101,Minor,Digital trunk RAI reception
4,21/07/2010,16:22:37,390, 11101,Minor,Digital signal synchronization established
5,21/07/2010,16:22:37,301, 11101,Minor,Digital trunk RAI reception
6,21/07/2010,16:21:59,391, 11101,Minor,Data Link established
7,21/07/2010,16:21:58,305, 11101,Minor,Data Link failure
Платы не синхронизированы.
Ползунок в положении В... А сопротивление выставлено какое? Должно быть 120 Ом.
Попробуйте другой патч-корд...
В п.1.4 для АТС, в которой плата мастер поставить None, а во второй АТС в этом же пункте указать плату PRI…
А конфиги обеих АТС слабо выложить?
ПОМЕНЯЛ ПАТЧ КОРД
PBX->QSIG line No.675 Port:1 (elapsed time from LPR reset) 01/01/01 00:28:52
L2: I SAPI:0 TEI:0
L3:
SETUP crn:0075 (O)
Bearer Capability: 90 90 A3 (3.1kHz Audio A-Law)
Channel Identity: A1 83 81 (channel=B1 pref.)
Calling Party Number: 09 80 32 34 35
Type of Number= Unknown, Numbering Plan= Private
Number= 245
Called Party Number: 89 37
Type of Number= Unknown, Numbering Plan= Private
Number= 7
02 01 1E 18 08 02 00 75 05 04 03 90 90 A3 18 03
A1 83 81 6C 05 09 80 32 34 35 70 02 89 37
QSIG line->PBX No.676 Port:1 (elapsed time from LPR reset) 01/01/01 00:28:52
L2: I SAPI:0 TEI:0
L3:
SETUP ACK crn:0075 (D)
Channel Identity: A9 83 81 (channel=B1 excl.)
00 01 18 20 08 02 80 75 0D 18 03 A9 83 81
PBX->QSIG line No.677 Port:1 (elapsed time from LPR reset) 01/01/01 00:28:52
L2: I SAPI:0 TEI:0
L3:
INFORMATION crn:0075 (O)
Called Party Number: 89 30
Type of Number= Unknown, Numbering Plan= Private
Number= 0
02 01 20 1A 08 02 00 75 7B 70 02 89 30
PBX->QSIG line No.678 Port:1 (elapsed time from LPR reset) 01/01/01 00:28:53
L2: I SAPI:0 TEI:0
L3:
INFORMATION crn:0075 (O)
Called Party Number: 89 31
Type of Number= Unknown, Numbering Plan= Private
Number= 1
02 01 22 1A 08 02 00 75 7B 70 02 89 31
QSIG line->PBX No.679 Port:1 (elapsed time from LPR reset) 01/01/01 00:28:53
L2: I SAPI:0 TEI:0
L3:
CALL PROCEEDING crn:0075 (D)
00 01 1A 24 08 02 80 75 02
QSIG line->PBX No.680 Port:1 (elapsed time from LPR reset) 01/01/01 00:28:53
L2: I SAPI:0 TEI:0
L3:
ALERTING crn:0075 (D)
Progress Indicator: 81 88
Description= “In-band information or appropriate pattern now available”
Location= “private network serving the local user”
00 01 1C 24 08 02 80 75 01 1E 02 81 88
PBX->QSIG line No.681 Port:1 (elapsed time from LPR reset) 01/01/01 00:29:23
L2: I SAPI:0 TEI:0
L3:
DISCONNECT crn:0075 (O)
Cause: 81 90
Cause Value= “#16 Normal clearing”
Location= “private network serving the local user”
02 01 24 1E 08 02 00 75 45 08 02 81 90
QSIG line->PBX No.682 Port:1 (elapsed time from LPR reset) 01/01/01 00:29:23
L2: I SAPI:0 TEI:0
L3:
RELEASE crn:0075 (D)
00 01 1E 26 08 02 80 75 4D
PBX->QSIG line No.683 Port:1 (elapsed time from LPR reset) 01/01/01 00:29:23
L2: I SAPI:0 TEI:0
L3:
RELEASE COMPLETE crn:0075 (O)
02 01 26 20 08 02 00 75 5A
Я ТАК ПОНИМАЮ ВСЕ ЗАРАБОТАЛО, НО ПОЧЕМУ КОГДЯ НА НАБИРАЮ 789( ТАКОГО НОМЕРА В ТОЙ АТС НЕТУ) ИДУТ ТАКИЕ ДИННЫЕ ГУДКИ, А НЕ КОРОТКИЕ
А Вы боялись! 😊
Все карашо!
Я ТАК ПОНИМАЮ ВСЕ ЗАРАБОТАЛО, НО ПОЧЕМУ КОГДЯ НА НАБИРАЮ 789( ТАКОГО НОМЕРА В ТОЙ АТС НЕТУ) ИДУТ ТАКИЕ ДИННЫЕ ГУДКИ, А НЕ КОРОТКИЕ
Дайте трассу такого звонка
нет а почему идет дозвон до несуществующего номера
нет а почему идет дозвон до несуществующего номера
На оператора звонок слетает.
Интересно, а чем же, все-таки закончилась история? Топикстартер, сообщите, плз, решили ли Вы свою проблему?
Всем спасибо. Все решилось заменой патч корда. А как сделать чтоб звонки не слетали на оператора а были короткие гудки при звонках на несуществующие номера?